Diagnostic accuracy study of three alcohol breathalysers marketed for sale to the public

Ashdown, Helen; Fleming, Susannah; Spencer, Elizabeth; Thompson, Matthew; Stevens, Richard · 2014 · OpenAlex-citations

DOI: 10.1136/bmjopen-2014-005811

archive: archived pipeline: cataloged

Get this paper ↗ (DOI — opens at the source; we link to it, we don't host it)

Abstract

OBJECTIVES: To assess the diagnostic accuracy of three personal breathalyser devices available for sale to the public marketed to test safety to drive after drinking alcohol. DESIGN: Prospective comparative diagnostic accuracy study comparing two single-use breathalysers and one digital multiuse breathalyser (index tests) to a police breathalyser (reference test). SETTING: Establishments licensed to serve alcohol in a UK city. PARTICIPANTS: Of 222 participants recruited, 208 were included in the main analysis. Participants were eligible if they were 18 years old or over, had consumed alcohol and were not intending to drive within the following 6 h. OUTCOME MEASURES: Sensitivity and specificity of the breathalysers for the detection of being at or over the UK legal driving limit (35 µg/100 mL breath alcohol concentration). RESULTS: 18% of participants (38/208) were at or over the UK driving limit according to the police breathalyser. The digital multiuse breathalyser had a sensitivity of 89.5% (95% CI 75.9% to 95.8%) and a specificity of 64.1% (95% CI 56.6% to 71.0%). The single-use breathalysers had a sensitivity of 94.7% (95% CI 75.4% to 99.1%) and 26.3% (95% CI 11.8% to 48.8%), and a specificity of 50.6% (95% CI 40.4% to 60.7%) and 97.5% (95% CI 91.4% to 99.3%), respectively. Self-reported alcohol consumption threshold of 5 UK units or fewer had a higher sensitivity than all personal breathalysers. CONCLUSIONS: One alcohol breathalyser had sensitivity of 26%, corresponding to false reassurance for approximately three people in four who are over the limit by the reference standard, at least on the evening of drinking alcohol. The other devices tested had 90% sensitivity or higher. All estimates were subject to uncertainty. There is no clearly defined minimum sensitivity for this safety-critical application. We conclude that current regulatory frameworks do not ensure high sensitivity for these devices marketed to consumers for a decision with potentially catastrophic consequences.

Provenance

The full processing record for this entry. Every stage of this paper's journey through the pipeline is logged — what ran, with which tool and model, how many attempts it took, and when it last completed.

StageOutcomeToolModelPromptAttemptsCompleted
discover success OpenAlex-citations 1 2026-06-19
archive success openalex 5 2026-06-26
extract success cached 2 2026-06-26
clean success clean 1 2026-06-19
chunk success chunk 1 2026-06-19
embed success embed Qwen/Qwen3-Embedding-8B 1 2026-06-19
promote success 1 2026-06-19
summarize skipped llm qwen3.6-27b-prismaquant summ-v5 1 2026-06-26
tag success vector_similarity 6 2026-06-19

Topics